Controls for DepotMini

Standard Control

Standard Control
  • time-mode, counter-mode and M-mode
  • any quantity of control parts and production parts per container
  • quantity recipes 10
  • differentiation production parts and control parts
  • single container emptying
  • available with DepotVacuum, DepotMini C and DepotMini R 
  • sampling in mode automatic
  • languages ger, fr, eng, it

Time Control

Time Control
  • time-mode and M-mode
  • quantity recipes 1
  • differentiation production parts and control parts
  • available with DepotMini R
  • language english

Operating modes

  • Time mode: The production and control containers are switched further after a fixed time. 
  • Counter mode: The production and control containers are switched further after a certain number of parts.
  • M mode: The production and control containers are switched further using a M code. 

Machine interface

  • DepotMini full in automatic mode, if all containers are full.
  • DepotMini ready in automatic mode. 


Emptying containers

Manual switched further for emptying the containers. 

Automatic mode

In automatic mode, the following signals are issued: 

  • DepotMini ready for operation
  • DepotMini full

Sampling

Probeentnahme